When reassembling:
Place the diaphragm assembly and floating valve in the drain hole of the
welded tub.
Make sure the reference mark is positioned correctly in the seal diaphragm
assembly seat.
When positioning the IDB lid, make sure it fits as far as it can go against
the reference point.
When reassembling:
Repeat the same steps in the reverse order, tightening the screws at a torque of 5 Nm.

14.7.2 Pressure chamber

Empty the drain circuit.
Lay the appliance onto its left side (the side where the detergent dispenser is).
Insert a flat-tip screwdriver between the pressure chamber and the hook
securing it to the welded tub.
Turn it anti-clockwise while at the same time removing the chamber.
Take care not to damage it.
Remove the pipe connecting to the analogue pressure switch.