Alarm
Description
NTC probe for wash cycle
E74
improperly positioned
Recirculation pump TRIAC
E84
"sensing" circuit faulty
Circulation pump TRIAC switch
E85
faulty
E87
Display board microprocessor faulty
Communication error between
E91
main PCB and display
Communication inconsistency
E92
between main PCB and display
(incompatible versions)
E93
Appliance configuration error
Incorrect configuration of
E94
washing cycle
Inconsistency between programme
E97
selector and cycle configuration
Communication error between
E98
main PCB - Inverter
E9C
Display board configuration error
Display board sensor/touch key
E9E
faulty
Electronically controlled valve
EC1
blocked with operating flowmeter
EC4
AGS current sensor faulty
Drain filter clogged
EF1
(drain phase too long)
Overdosing of detergent
EF2
(too much foam during drain phases)
EF3
Aqua control system intervention
Water fill pressure too low, no signal
EF4
from flowmeter and electronically
controlled valve is open
EF5
Unbalanced load
Technical Support - MDM
Possible fault
Wiring faulty; NTC probe for wash cycle improperly positioned;
NTC probe faulty; Main PCB faulty.
Main circuit board faulty.
Wiring faulty; Recirculation pump faulty; Main PCB faulty.
If this continues, replace the display board.
Wiring faulty; Control/display circuit board faulty;
Inverter Board faulty, Main circuit board faulty.
Incorrect control/display PCB;
Incorrect PCB (does not correspond to the model).
Main PCB faulty (incorrect configuration data).
Main PCB faulty (incorrect configuration data).
Main PCB faulty (incorrect configuration data).
Incompatibility between main PCB and Inverter.
Display board faulty.
Display board faulty.
Faulty wiring; Faulty/blocked solenoid; PCB faulty.
Main board faulty.
Drain filter clogged/dirty;
Drain hose blocked/kinked/too high.
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Water leaks onto base frame; Aqua control system faulty;
Drain pump coil overheating/broken.
Tap closed; Water fill pressure too low.
Final spin phases skipped.
59/104
Machine status/action
The heating phase is skipped
Safety drain cycle - Cycle stops
with door open
Safety drain cycle - Cycle stops
with door open
No action to be taken
----------------
Cycle blocked
Cycle blocked
Cycle blocked
Cycle blocked
Cycle blocked
----------------
----------------
Cycle stops with door locked
Drain pump continues to operate
(5 min. on, then 5 min. off. etc.)
Spin speed reduced to safety speed
of 150 rpm
Warning displayed at the end of cycle
Warning displayed after 5 attempts
or by the specific LED
Appliance drain
----------------
----------------
Reset
RESET
RESET
RESET
START
ON/OFF
RESET
RESET
ON/OFF
ON/OFF
ON/OFF
RESET
ON/OFF
START
ON/OFF
RESET
ON/OFF
RESET
RESET
START/RESET
RESET
ON/OFF RESET
RESET
START/RESET
599 77 39-16 Rev. 00