Summary of Contents for IMG STAGE LINE STROBE-324LED
Page 1
LED Stroboscope STROBE-324LED Order No. 38.7990 INSTRUCTION MANUAL ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS...
TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to set the unit 5. How to control the unit 6. DMX512 Configuration 7. DMX512 Connections 8. Troubleshooting 9. Fixture Cleaning...
Page 3
1. Safety Introductions Please read the instructions carefully which includes important information about the installation, operation and maintenance. WARNING Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet. Unpack and check carefully there is no transportation damage before using the fixture.
2. Technical Specifications DMX 1/2/4/8/10/12 channels switchable. Smooth 0~100% dimming and variable strobe speeds. Three operation modes: DMX, Mater/Slave mode, Sound Active. Ideal for discotheques, clubs, bars, parties, Mobile DJs, ect. Power Supply: 120~230V 50/60Hz Power consumption: 150W ...
Page 5
○ 3 Button: To select the programming functions with short press. MENU DOWN To go backward in the selected functions To go forward in the selected functions ENTER To confirm the selected functions ○ 4 DMX input: For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal. ○...
Page 6
Blackout Mode Display LED mode On – Off Display Inverse disp-dsip Auto Test Temperature Fixture hours Fixture Time 0 ~ 9999 Version V 10 DMX 512 Address Setting Press the MENU button up to when the is shown on the display. Pressing the ENTER button and the display will blink.
Page 7
Show Mode Press the MENU button up to when the is shown on the display. Pressing the ENTER button, Use the DOWN and UP button to select the (Random show) or (show 1) or (Show 2) or … or (Manual). Once selected, press the ENTER button to store or automatically exit menu mode without any change after 7 seconds.
Page 8
Blackout mode Press the MENU button up to when the is shown on the display. Pressing the ENTER button, Use the DOWN and UP button to select the (blackout) or (normal). Once selected, press the ENTER button to setup or automatically exit menu mode without any change after 7 seconds.
Fixture Hours Press the MENU button up to when the is blinking on the display. Pressing ENTER button and the display will show the number of working hours of the unit. To go back to the functions press the MENU button. Software version Press the MENU button up to when the is blinking on the display.
functions without any change press the MENU button again. If you use please refer to the following diagram to address your DMX512 channel for the first 4 /2 units. Channel Mode Unit 1 Unit 2 Unit 3 Unit 4 1 Channel 2 Channel 4 Channel 8 Channel...
Page 11
2- CH mode: 2 CH Mode open 000 - 255 Master dimmer 9-255 strobe slow to fast 4-CH mode: 4 CH Mode 000-007 Led Blackout 008-027 Led chase1 028-047 Led chase2 048-067 Led chase3 068-087 Led chase4 088-107 Led chase5 open 108-127 Led chase6...
7. DMX512 Connections mode connection: Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable.
B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.