The vertical scale is the measured value in decibels.
The horizontal scale is the frequency range in megahertz.
To see help for the screen, tap
To switch between results for the main unit and the remote,
tap REMOTE or MAIN.
The margin at the cursor's location. The margin is the difference
between the measured value and the limit. The margin is
negative if the pair failed.
The measured value at the cursor's location.
When you first look at the plot, the cursor is at the frequency of
the worst margin. To move the cursor to the worst value, tap
WORST VALUE. (The insertion loss plot is different. See the
Technical Reference Handbook.)
To see the plots for pairs, tap
on the plot, touch
PAIRS window. Select the pairs you want to see, then tap OK.
When you first look at the plot, the cursor is at the frequency of
the worst margin. To move the cursor to the worst value, tap
WORST VALUE (). The box at the bottom of the cursor shows
the frequency at the cursor's position.
To move the cursor to other points, touch and drag the yellow
circle at the top of the cursor.
To move the cursor in small increments, tap the yellow circle,
then tap the arrow buttons that show on the plot (
The overall result for the test. If you look at pairs, the result is for
those pairs. If the result shows an asterisk, see "PASS*/FAIL*
Results" on page 40.
To zoom in and out, use the pinch, reverse-pinch, and double-
tap gestures on the touchscreen. You can also use the zoom
controls to change the magnification on the frequency and
decibels scales independently. See Figure 6 on page 19.
riešenia na presné meranie
Chapter 2: How to Certify Twisted Pair Cabling
or
Twisted Pair Autotest Results
.
or
. To select pairs to show