Remove The Cross Flow Fan And The Motor; Remove The Vertical Louver - Gree GWH18UC-K3DNA1A/I Service Manual

Indoor/outdoor units with remote control
Hide thumbs Also See for GWH18UC-K3DNA1A/I:
Table of Contents

Advertisement

Steps

8.Remove the cross flow fan and the motor

a
Remove the screws fixing the motor press plate
and the step motor. Remove the motor press
plate and the step moor.
b
Remove the screws fixing the cross flow fan
and the motor.
c
Remove the motor.
d
Remove the cushion of the bearing.

9.Remove the vertical louver

Loosen the clasp of the vertical louver and the
chassis. Remove the vertical louver.
Procedure
cushion
motor press plate
step moor
screw
cross flow fan
vertical louver
motor