INSTALLATION
2.2.1
Lynx™ BT as Slave
Once set as Slave, a Lynx™ BT reader requires no particular configuration for
communication, however some radio parameters can be set to increase system
performance and data transmission security. At startup the reader can only wait for
the Master to initialize the radio communication.
The following is a general procedure recommended for Lynx™ BT Slave
applications:
1.
Power up the remote Bluetooth
2.
Power up the Lynx™ BT reader within radio range (10 meters).
Any modifications to the radio configuration should be made at this time before
the radio connection takes place.
3.
From the remote Bluetooth
(according to the procedure given in the documentation of the Bluetooth
device), to recognize the Lynx™ BT reader(s) within radio range.
4.
Check that "Lynx BTx00
5.
Request to open an SPP connection with Lynx™ BT, making sure to disable any
required PIN and/or pairing parameters. Lynx™ BT is always discoverable and
connectable without any required PIN.
If the PIN of the Bluetooth
PIN "1234". The Lynx™ BT Slave will emit four ascending tones
indicating radio connection.
NOTE
After the Lynx™ BT reader(s) indicate radio connection (see also par. 10.1), you can
start sending barcodes.
®
Master device (example Laptop or PC).
®
Master device, execute the Discovery procedure,
" is shown among the discovered devices.
®
Master device cannot be disabled, use the