Electrical Connection - S&P Quadro-250 Instruction For Use & Installation Instructions

Radiant panel
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
- Place the panel at a distance of at least 30 cm from the side
walls and at least 50 cm if these will are covered with synthetic or
inflammable materials.
- Place the panels at least 30 cm from windows.
- Always place the panel at a minimum height of 1.80 m.

ELECTRICAL CONNECTION

WARNING: Before making the electrical connection, ensure that the
supply is disconnected.
A connection box that contains the terminal strip to connect the electric cable
can be found at the rear of the panel.
Remove the connection box cover, by unscrewing the holding-down screw.
Make a 16 mm hole in the cover of the connection box so that it coincides with
the visible pre-incision area, to insert the supply cable (at least 2x0.75 mm2)
into compartment where the connection strip is located.
12