Leb Electronics STONE 180 Instructions, Maintenance, Installation And Warnings Manual page 19

Underground 180 degree gate automation system
Table of Contents

Advertisement

MD
Type of risks
Ann. 1
1.3.7
Mechanical risks due to
movement of the leaf.
1.3.8
1.4
[7] Dragging of the
hands on the hinges side
edge (Figure 1, risk D).
[8] Dragging of the feet
on the lower edge
(Figure 1, risk E).
[9] Dragging of the
hands on the drive unit
(Figure 1, risk F).
[10] Dragging, hooking
and cutting due to the
shaping of the mobile
leaf (Figure 1, risk G).
Electrical and electromagnetic
compatibility risks
[11] Direct and indirect
contacts.
Dispersion of electrical
1.5.1
energy.
1.5.2
[12] Risks relating to
electromagnetic
compatibility.
1.5.10
1.5.11
Safety and reliability of
drive unit and control and
safety devices.
[13] Safety conditions in
the event of
1.2
malfunctioning and
power failure.
[14] Energy types other
than electrical energy
1.5.3
[15] Actuation and
disabling of the drive
unit.
1.2.3
1.2.4
[16] Power supply
switch.
Evaluation criteria and solutions to be adopted
(Tick the box corresponding to the solution adopted)
Check that there is a clearance > 25 mm,
or:
attach guards that prevent fingers from being inserted (for example a
rubber strip).
The clearance between the gate and ground must prevent the risk of
dragging of the feet.
N.B. Should, due to the slope of the ground, the clearance vary, guards
should be attached (e.g. rubber strips).
If the distances between the drive unit and the leaf vary, check on the
presence of a clearance > 25 mm, or attach guards (e.g. covers or strips in
rubber).
Eliminate or protect any sharp edges, handles, projecting parts etc. (for
example by means of covers or strips in rubber).
Use CE-marked components and materials pursuant to the Low Voltage
Directive (73/23/EEC).
Carry out the electrical connections, connection to the mains, earth
connections and relevant checks, in accordance with current regulations and
as indicated in the installation manual of the drive unit.
N.B. If the electrical supply line is already set up (via both a socket and a
connector block), declarations of conformity to Italian law no. 46/90 are not
necessary.
Use CE-marked components pursuant to the EMC Directive (89/336/EEC).
Carry out the installation as indicated in the manual for installation of the drive
unit.
Use drive units which comply with the standard EN 12453 and safety
devices which comply with the standard EN 12978.
If hydraulic drive units are used, they must comply with the standard EN
982; or
if pneumatic drive units are used, they must comply with the standard EN
983.
Check that, after a fault or power failure, the drive unit restarts safely
without creating hazardous situations.
Install an omnipolar switch for electrical insulation of the door/gate, in
accordance with current laws. This switch must be positioned and protected
against accidental or unauthorised actuation.
-
5 -
UNAC Guide No. 2- July 2005