Leb Electronics STONE 180 Instructions, Maintenance, Installation And Warnings Manual page 10

Underground 180 degree gate automation system
Table of Contents

Advertisement

STONE 180
Cable 4x1,5 mm
Common
Motor OPEN
Motor CLOSE
Ground
Capacitor connection
- In the gearmotor STONE180 connect the 12uF capacitor between the
black wire (Open) and the brown wire (Close) of the electric engine.
Limit switches cable
The device is equipped with two magnetic Limit switches. From the
Limit switches block three wires come out. In the following table the
data concerning the Limit switches cable, required for the connection
to the control board, are reported.
Cable 3 x 1,5 mm
Common
Limit switch OPENING
Limit switch CLOSING
Manual unblocking
The manual unblocking causes the release of the device
from the wing, allowing the manual displacement of this one. It can be
used in case of electric voltage lack or of installation failure. The
unblocking is made through a key that is to be kept by user in a sure and
easily reachable place. In order to obtain the unblocking of the device,
proceed in the following way:
- Insert the socket spanner into the hole fitted on the traction arm (fig.17).
- Turn the socket spanner in the direction indicated in fig.17, then open the
wing of the gate by hand.
- To lock, bring the wing back to the hooking position with the traction arm.
- Turn the socket spanner in the opposite direction and simultaneously
push the wing to hook it.
STONE 24
Color
Cable 2x1,5 mm
Blue
Positive motor
Black
Negative motor
Brown
Yellow-Green
-9 -
ENGLISH
ITALIANO
Color
Red or Green
Black or Brown
Colour
Blue
Black
Brown