AUTOTROL 460i AND 460TC CONTROL SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS
www.pentairaqua.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUTOTROL 460i and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair AUTOTROL 460i

  • Page 1 AUTOTROL 460i AND 460TC CONTROL SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS www.pentairaqua.com...
  • Page 2: Table Of Contents

    CONTENTS Self-Adjusting Reserve 460I ELECTRONIC DEMAND SYSTEM .........2 “Reserve” refers to the amount of soft water that may be SPECIAL FEATURES 460I ............2 needed for the next 24 hours. The microprocessor calculates PROGRAMMING THE 460I ...........3 how much soft water was used and adjusts the reserve CONTROL FEATURES 460I ..........3 capacity accordingly at the end of each day.
  • Page 3: Programming The 460I

    PROGRAMMING THE 460i Capacity Setting Plug the wall mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer Move the upper jumper to the set of pins next to the word CAPACITY (Figure 4). Press the black TIME SET Button until plug into the transformer plug receptacle on the timer.
  • Page 4: Programming The 460Tc

    CONTROL FEATURES 460i CONTINUED Manual Regeneration Time of Day Setting Electricity is used only to run the timer and to rotate With the jumper on the set of pins next to the word TIME the camshaft. All other functions are operated by water (Figure 6), set the time of day to the closest hour by pressing the black TIME SET button.
  • Page 5: Adjustment Of Brine Control 460I/460Tc

    ADJUSTMENT OF BRINE CONTROL 460i/460TC The amount of salt placed into the regenerant storage tank has nothing to do with the amount of salt used during the regeneration cycle. Water will dissolve and absorb salt only until it becomes saturated. A given amount of brine (salt saturated water) contains a specific amount of salt.
  • Page 6: Troubleshooting

    TROUBLESHOOTING Your water conditioning system is designed and manufactured for efficient, low maintenance service. However, if problems do occur, this section provides a list of possible causes and solutions. You can solve some problems yourself, such as low salt in the salt storage tank or a blown household fuse.
  • Page 7 TROUBLESHOOTING CONTINUED Problem Cause Solution If water flow display is not operative, refer to "No Same as "No water flow display when water is Control will not regenerate water flow display when water is flowing". flowing". automatically but will regenerate Defective circuit board.
  • Page 8 All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services. Pentair reserves the right to change specifications without prior notice.