Air-to-water heat pump

Advertisement

air-to-water heat pump
Simple
reliable
,
efficient split heat pump!
CS controller
Equipped with
60
Cooling or
heating
U
se
the YUNA II air-to-water split heat pump is designed for
heating applications in new, existing individual homes and
small businesses.
R
ange
YuNa II's range is composed by 6 single-phase and three-
phase models.
Operation in cooling mode with an outdoor temperature of
0°C to 46°C (only three-phase units).
Operation in heating mode with an outdoor temperature of
-20°C to +30°C.
C
onfoRmity
Low Voltage Directive 2006/95/eC
emC: electromagnectic Compatibility 2004/108/eC
peD: pressure equipment Directive 97/23/eC
Weee: Waste electrical & electronic equipment 2012/19/eu
Rohs: Restriction of hazardous substances Directive 2011/65/ue
heat pumps - aIR CONDItIONING - ReFRIGeRatION - aIR haNDLING - heat eXChaNGe - Na 15.739 a
,
*
Heating nominal capacity :
Cooling nominal capacity :
**
410A
*Reversible mode only with three-phase models
When installed alone, YuNa II is compatible with low to
medium temperature emitters (underfloor heating, fan coil
units, water cassettes, radiators, mixed installations, etc.).
YuNa II is also compatible with high temperature emitters for
boiler backup operation.
each device is tested in the factory and delivered ready for
operation.
If the heat pump is the only source of heat:
Below this temperature, heating must be provided by a
separate heating source or an additional electrical supply.
If the heat pump is used for backup operation:
Operates down to the equilibrium point (temperature below
which the heat pump can no longer keep up with heating
needs). Below this point, the heat pump and boiler run
alternately (heat pump OR boiler).
4 to 15kW
14 to 16kW
** except three-phase models
1

Advertisement

Table of Contents
loading

Summary of Contents for CIAT Yuna II 5H

  • Page 1 air-to-water heat pump Simple reliable efficient split heat pump! CS controller Equipped with 4 to 15kW Heating nominal capacity : 14 to 16kW Cooling nominal capacity : 410A Cooling or heating *Reversible mode only with three-phase models ** except three-phase models the YUNA II air-to-water split heat pump is designed for When installed alone, YuNa II is compatible with low to heating applications in new, existing individual homes and...
  • Page 2: Advanced Technology

    Directive that sets mandatory requirements for energy related products (erp) to improve READY their energy efficiency. CIat supports initiatives to reduce the environmental impact of its products. Features ■...
  • Page 3: Environmental Care

    air-to-water heat pump Environmental care DC inverter twin-rotary compressor ■ Non-ozone depleting refrigerant R410a: ■ advanced technology provides maximum energy-efficiency with high capacity available at peak conditions and optimised - Chlorine-free refrigerant of the hFC group with zero ozone efficiency at low and mid compressor speeds. Yuna II DC depletion potential inverter uses Intelligent power Drive unit (IpDu) hybrid - high-density refrigerant, therefore less refrigerant required...
  • Page 4: Economical Operation

    Units Outdoor unit Indoor unit Yuna II 5H 5 kW nominal capacity Heating only, 1 zone, max. heating capacity 6.5 kW with 3 kW 1-ph electric heater backup Yuna II 6H 6.5 kW nominal capacity...
  • Page 5 air-to-water heat pump hysiCal Data oUtDooR anD inDooR Units Outdoor unit (heat pump) 11HK 12HTK 15HTK Indoor unit (confort module) 5-63D 5-63D 9-113D 9-113D 12-156D 12-156D Cooling Nominal capacity 3.57 4.73 5.95 10.3 12.6 kW / kW 3.07 2.88 3.41 3.17 Eurovent class cooling Full load performances*...
  • Page 6: Outdoor Units

    air-to-water heat pump Yuna II leCtRiCal Data oUtDooR anD inDooR Units Outdoor unit 11HK 12HTK 15HTK Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 400-3+N-50 400-3+N-50 Voltage range V-ph-Hz 198-264 198-264 198-264 198-264 400-3N-50 400-3N-50 Full load current 15.4 15.4 Fuse rating* Operating current 6.91 9.43...
  • Page 7: Operating Limits

    air-to-water heat pump peRating limits Cooling mode Heating mode (12HT and 15HT only) Maximum outside temperature 46 °C 30 °C Maximum leaving water temperature 18 °C 60 °C Minimum outside temperature 0 °C -20 °C Minimum leaving water temperature 4 °C 20 °C Operating range, cooling mode Operating range, heating mode...
  • Page 8 air-to-water heat pump Yuna II imensions oUtDooR Units 5H, 6H 9H, 11H, 12HT, 15HT Dimensions, mm Weight, kg 9H, 11H 1360 12HT, 15HT 1360 Rain hose anD base pan knoCkoUts In case of draining through the drain pipe, attach the drain Open the knockout holes in the base pan to improve the nipple (a) and use a drain hose with an inside diameter of 16 drainage capacity.
  • Page 9 air-to-water heat pump leaRanCes oUtDooR Units Single unit installation 1000 Multiple unit installation 1000 2000 1500 Note: the height of any obstacle at both the front and rear should be less than the outdoor unit height. heat pumps - aIR CONDItIONING - ReFRIGeRatION - aIR haNDLING - heat eXChaNGe - Na 15.739 a...
  • Page 10 air-to-water heat pump Yuna II imensions inDooR Unit leaRanCes inDooR Unit heat pumps - aIR CONDItIONING - ReFRIGeRatION - aIR haNDLING - heat eXChaNGe - Na 15.739 a...
  • Page 11 air-to-water heat pump en14511-3:2013 eating CapaCities in aCCoRDanCe with Yuna II Outside air dry-bulb (wet-bulb) temperature, °C -20 (-21) -15 (-16) -7 (-8) °C kW/kW kW/kW kW/kW Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 2.44...
  • Page 12 air-to-water heat pump Yuna II en14511-3:2013 eating CapaCities in aCCoRDanCe with Yuna II Outside air dry-bulb (wet-bulb) temperature, °C 7 (6) 10 (9) 20 (19) °C kW/kW kW/kW kW/kW Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom...
  • Page 13 air-to-water heat pump en14511-3:2013 ooling CapaCities in aCCoRDanCe with Yuna II Outside air Temperature, °C °C kW/kW kW/kW kW/kW Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom Nom Min Max Nom Min Max Nom 12.15 6.19 15.44 6.05 4.67 5.20...
  • Page 14 air-to-water heat pump Yuna II ptions zone kit Physical data, two-zone kit Dimensions Unit H x L x D 485 x 450 x 330 Packaging H x L x D 565 x 530 x 410 Unit weight Gross weight Hydronic data Water connections 1”...
  • Page 15 air-to-water heat pump RessURe CiRCUlating pUmp 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.00 0.10 0.20 0.30 0.40 0.50 0.60 Water flow rate, l/s Water flow rate, l/s high water pump speed medium water pump speed Low water pump speed imensions zone kit 30.5...
  • Page 16 air-to-water heat pump Yuna II & leaRanCes zone kit zone kit with Dhw way valve fitteD Connected to the Yuna II's indoor module Detached from the Yuna II's indoor module heat pumps - aIR CONDItIONING - ReFRIGeRatION - aIR haNDLING - heat eXChaNGe - Na 15.739 a...
  • Page 17: Domestic Hot Water

    air-to-water heat pump (Dhw) hysiCal Data ptions DomestiC hot wateR 300 DHW tank Water tank size Number of coils Electric heater backup Operating temperature range °C 5 to 95 Operating pressure DHW 0 to 8 Operating pressure heat exchangers 0 to 6 Ambient operating temperature range °C 5 to 45 °C...
  • Page 18 Management certifié TàP ANGLAIS This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modifi cation it feels appropriate without prior notifi cation. Head offi ce 700 Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42...

Table of Contents