Ricoh D027 Service Manual page 36

Table of Contents

Advertisement

No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Defective fusing unit
1.
Turn the main power switch ON/OFF.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
IH inverter input voltage error
The IH inverter detects 70V or less/140V or more for 10 seconds.
Unusual input voltage
581
D
Disconnected CN981 on the IH inverter
Defective IH inverter
1.
Check CN981 on the IH inverter.
2.
Replace the IH inverter.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
IH inverter current error at power on
The output current from the IH inverter does not reach the proper value
when the IH inverter turns on.
Disconnected power input terminal 1 and 2
Defective IH inverter
582
D
Defective IH coil unit
Defective fusing unit
1.
Check the power input terminals 1 and 2.
2.
Replace the IH inverter.
3.
Replace the IH coil unit.
4.
Replace the fusing unit.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
585
A
IH coil unit full power (1250W) error
SM
3-39
http://www.manuals4you.com
SC Tables
D027/D029 APPENDICES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D029

Table of Contents