No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
1.
Check the connection between the controller board and the BICU.
2.
Replace the BICU.
3.
Replace the controller board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: K
The PFGATE ON signal still asserts within 5 seconds after
231
D
processing the image in normal job or MUSIC for end position [K].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after
232
D
processing the image in normal job or MUSIC for start position [Y].
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: Y
The PFGATE ON signal still asserts within 5 seconds after
233
D
processing the image in normal job or MUSIC for end position [Y].
The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
234
D
FGATE ON error: M