Ricoh D027 Service Manual page 16

Table of Contents

Advertisement

No.
Type
position
sensor.
2.
Replace
the
PCU.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
396
D
Drum/Development motor error: K
397
D
Drum/Development motor error: M
398
D
Drum/Development motor error: C
399
D
Drum/Development motor error: Y
The machine detects a High signal from the drum/development motor
for 2 seconds after the drum/development motor turned on.
Overload on the drum/development motor
Defective drum/development motor
Defective harness
-
-
Shorted 24 V fuse on the PSU
Defective interlock system
1.
Check or replace the harness.
2.
Replace the drum/development motor.
3.
Replace the 24V fuse on the PSU.
SM
Details (Symptom, Possible Cause, Troubleshooting Procedures)
3-19
http://www.manuals4you.com
SC Tables
D027/D029 APPENDICES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D029