3. If the tool is not required, keep it in a clean and dry place.

8.2 Periodic Inspection

The stripping hand tool should be inspected at regular intervals.
1. Remove any remains that could affect the working of the hand tool.
2. Make sure the bearing studs are inserted and held in position by the lock washers.
3. Close the tool handles fully and allow them to open freely. If the tool handles do not open quickly and
completely, the tool head spring is damaged and must be replaced.
4. The bearing studs must be regularly lubricated with a light machine oil and protected against
contamination.
9

Spare and Wear Parts

The following table lists the spare parts for the stripping hand tool.
Operator manual 411-18508 / TE P/N 1-744014-8
The tension springs should preferably be replaced by the TE Connectivity customer service department.
Item
1
Replacement stripping blades
2
Lock washer
Component
Tension spring kit
Page 16 / 16
Headless screw
Figure 9
TE P/N
1579006-7
2-1579025-0
411-18508 Rev C
Bearing stud