Page 1
C.A 1510 MEASUREMENT OF INDOOR AIR QUALITY CO AMBIENT TEMPERATURE RELATIVE HUMIDITY ENGLISH User’s manual GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Page 2
Thank you for purchasing a C.A 1510 indoor air quality meter. For best results from your instrument: read this user manual carefully, comply with the precautions for use. WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
CONTENTS PRESENTATION ..................................4 Introduction....................................... 4 Side view ......................................4 Side and back views ..................................5 The display unit ....................................6 USE ......................................7 Installing the batteries ..................................7 Switching the device on ................................... 7 Switching the device off ................................... 7 Making a measurement ...................................
The C.A 1510 is an instrument for measuring physical quantities that combines the following functions: Measurement of the concentration of carbon dioxide in the air (CO ...
SIDE AND BACK VIEWS Notch for hanging up the device Non-skid pads Magnet for attachment to a metallic surface Battery compartment cover Micro - USB connector GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
THE DISPLAY UNIT Display of the level of CO Display of the temperature Display of the relative humidity Indicates blinking Symbols Designation MEM_FULL Memory full Surveillance of the level of CO Surveillance of crossing of CO , temperature, and humidity comfort zone thresholds Maximum value Minimum value Energy-saving operating mode...
2. USE INSTALLING THE BATTERIES See §5.2. SWITCHING THE DEVICE ON SWITCHING THE DEVICE OFF 2.3.1 Manual switching off Manual switching off is blocked if a programmed recording session (P_REC) is in progress. 2.3.2 Automatic switching off In the portable mode, the device switches itself off automatically after 15 minutes of inactivity. Automatic switching off is de-activated in the other modes (1D or 3D, ECO, P_REC), and in the MIN MAX and M_REC functions, if the Bluetooth or USB link is active or if the device is connected via the USB mains adapter.
PORTABLE MODE The portable mode is the mode the device starts up in. It is in this mode that the device makes the most measurements: one every 15 seconds. It is therefore highly responsive to changes in air quality. This mode is used to inspect several rooms one after another. Install the device in a room and wait for the CO measurement to stabilize (approximately 10 minutes).
Page 9
2.6.2 Operation of the visible and audible warnings 1D mode: Activation of the visual (and, if activated, audible) warnings during overshoots of the CO thresholds. S1 = Low threshold = 1000 ppm S2 = High threshold = 1700 ppm Level of CO <...
Page 10
3D mode: Activation of the visual (and, if activated, audible) warnings during overshoots of the temperature, humidity, and/or comfort zones. Example of display with no overshoot of the , temperature, and humidity comfort zones Back-lighting off Optimum comfort zone indicator: Example of display with overshoot of the temperature and...
ECO MODE (ENERGY SAVING) The ECO mode is used when the device is left to measure the air quality in a room over a longer period. The backlighting and the buzzer are deactivated, and CO is measured only once every 10 minutes. This saves the batteries. In addition, the device sets itself to sleep mode at night, from 4:30 p.m.
MIN MAX FUNCTION This function displays the maximum and minimum measured values in addition to the current value: the device compares each new measurement to those displayed. If the new measurement is greater than the former MAX value or less than the former MIN value, it replaces them in the display.
2.10 HOLD FUNCTION (HOLDING THE MEASUREMENT) Pressing HOLD freezes the digital display on the last measurement displayed. Activating the function does not entail interruption of recording or of the current mode, but access to the other functions of the device is disabled. To stop the function 2.11 M_REC FUNCTION (MANUAL RECORDING)
2.13 ACTIVATION OF THE AUDIBLE WARNING (BUZZER) Deactivation Activation First press the ECO key, then, Repeat the operation. while keeping it pressed, press the MODE key. There is no buzzer if the ECO mode is active. 2.14 CHANGE OF UNIT OF TEMPERATURE The choice of unit of temperature is preserved when the device is switched off.
In the Windows bar, look for the Bluetooth logo, right-click on it, and choose Add a peripheral. If the Bluetooth logo is not present, go to Peripherals and printers in the Windows menu. Then choose Add a peripheral. The PC searches its environment for Bluetooth-compatible devices. When the C.A 1510 is detected, select it and click on Next. ...
RECORDING Memory: 1,000,000 measurements (8 MB) FAT12 Format ENVIRONMENTAL CONDITIONS Use indoors Operating range -10 to +60°C and 5 to 95%RH Range in storage (without battery) -20 à +60°C Altitude <2.000m MECHANICAL CHARACTERISTICS Dimensions (L x W x H) 125 x 65.5 x 32 mm Weight approximately 190 g Protection class...
5. MAINTENANCE Except for the batteries, the instrument contains no parts that can be replaced by personnel who have not been specially trained and accredited. Any unauthorized repair or replacement of a part by an "equivalent" may gravely impair safety. CLEANING Disconnect the instrument completely and switch it OFF.
Like all measuring or testing devices, the instrument must be checked regularly. This instrument should be checked at least once a year. For checking and calibration, contact one of our accredited metrology laboratories (information and contact details available on request), at our Chauvin Arnoux subsidiary or the branch in your country.
6. WARRANTY Except as otherwise stated, our warranty is valid for twelve months starting from the date on which the equipment was sold. Extract from our General Conditions of Sale provided on request. The warranty does not apply in the following cases: ...
7. TO ORDER C.A 1510 indoor air quality meter ........................... P01651010 The device is anthracite grey. It is delivered in a compact metal carrying case with: 2 LR6 batteries One mains-USB adapter One USB - micro USB cord 1.80 m long ...
ACCESSORIES AND REPLACEMENT PARTS Field calibration kit ............................... P01651022 Carrying case ..............................P01298071 Desktop support ..............................P01651021 Wall mount ................................P01651020 It is attached to the wall. It can be used to protect the device against theft by adding a padlock.