ZC Can Placement
Place the zc can inside the enclosure. The zc can must be placed so the front edge of the mounting flanges
are flush with the enclosure opening. Secure the enclosure to the floor protection (and sub-floor) with screws.
When venting horizontally the rear vent shield must be installed over the top of the zc can. When installed,
the rear vent shield should contact the thimble (it acts as a heat shield above the vent.
Secure the zc can to the
floor protection (and sub
floor) with screws.
2-1/2" Min.
(both sides)
When in place these tabs
must be flush with the
enclosure opening.
Page 7 of 8
ZC Kit – Large Pellet Insert
(99200149)
Floor Protection
10/9/06
For rear vent appliations, slide the
rear vent shield all the way back until
it contacts the wall thimble.