AEMC 400D-6 User Manual

AEMC 400D-6 User Manual

Digital flexprobe
Hide thumbs Also See for 400D-6:

Advertisement

Quick Links

400D-6
DIGITAL FLEXPROBE
®
400D-10
400D-60
400D-120
4000D-14
User Manual
ENGLISH
ShopAEMC
www.
.com
1.877.766.5412
Shop for AEMC products online at:

Advertisement

Table of Contents
loading

Summary of Contents for AEMC 400D-6

  • Page 1 400D-6 DIGITAL FLEXPROBE ®  400D-10 400D-60 400D-120 4000D-14 User Manual ENGLISH ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 2 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 3: Table Of Contents

    4.2 Electrical .................13 4.3 Variations in Range of Use .............14 4.4 Typical Frequency Response Curves ........15 4.5 Power Supply ................15 4.6 Environmental .................16 4.7 Mechanical ................16 4.8 Safety ..................16 4.9 Electromagnetic Compatibility ..........16 Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 4 5. MAINTENANCE ................17 5.1 Cleaning ..................17 5.2 Replacing the Batteries ............17 5.3 Repair and Calibration ............18 5.4 Technical and Sales Assistance ..........18 5.5 Limited Warranty ..............19 5.6 Warranty Repairs ..............19 Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 5: Introduction

    CHAPTER 1 INTRODUCTION Thank you for purchasing an AEMC Digital Flexbprobe. ® For best results and for your safety, read the enclosed operating instructions carefully and comply with the precautions for use. PRECAUTIONS BEFORE USE This instrument is protected against voltages of not more than...
  • Page 6: International Electrical Symbols

    Save the damaged packing container to substantiate your claim. Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 7: Ordering Information

    Ordering Information Digital FlexProbe Model 400D-6 w/6 ft Lead ® ) ..........Cat. #2153.30 (TRMS, 4A , 40A , 400A Digital FlexProbe Model 400D-10 w/6 ft Lead ® ) ..........Cat. #2153.31 (TRMS, 4A , 40A , 400A Digital FlexProbe Model 4000D-14 w/6 ft Lead ®...
  • Page 8: Product Features

    The optional articulating, magnetic Multifix mounting system accessory makes it simple to hang on a wall, door, table edge or clip onto a belt. Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 9: Control Features

    (>2s) Digital FlexProbe ® 1. Flexible sensor - Model 400D (6", 10", 60", 120") - Model 4000D (14") 2. Sensor opening/closing lever 3. Shielded lead 4. Protective housing 5. LCD display 6. ON/OFF button 7. HOLD button Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 10 • Attach it to a metal surface using the built-in magnet • Attach it to a door top or the edge of a table Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 11: Operation

    • Press the button to turn the instrument on. Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 12: Measurement

    The HOLD symbol is displayed. HOLD The device continues to make measurements, but the display is frozen. To release it, press the HOLD button again. Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 13: Search For Maximum

    Turn off the device by pressing the button. Press the yellow opening lever to open the flexible sensor. Remove the sensor from the conductor. Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 14: Specifications

    Position of the conductor centered in the measurement coil Shape of the measurement coil nearly circular Electrical Model 400D-6 / 400D-10 / 400D-60 / 4000D-120 Display Range 400A Measurement Range 0.020 to 3.999A 4.00 to 39.99A 40.0 to 399.9A Measurement Range (max) 0.100 to 3.999A...
  • Page 15: Variations In Range Of Use

    — ≥ 50 dB < 1ct ≥ 60 dB < 1ct Housing: ≥ 30 dB Housing: 43 dB Sensor: ≥ 40 dB Sensor: 50 dB Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 16: Typical Frequency Response Curves

    The low battery condition is acknowledged by a blinking symbol on the display. When lit steadily, the batteries must be replaced (see § 5.2). Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 17: Environmental

    Sensor Length: 400D-6: 6" (170mm) 400D-10: 10" (250mm) 400D-60: 60" (1524mm) 400D-120: 120" (3048mm) 4000D-14: 14" (350mm) Sensor Diameter: 400D-6: Ø 1.77" (45mm) 400D-10: Ø 2.75" (70mm) 400D-60: Ø 19" (483mm) 400D-120: Ø 38" (965mm) 4000D-14 : Ø 3.94" (100mm) Weight: 0.29 lbs (130g) approx...
  • Page 18: Digital Flexprobe ® Models 400D & 4000D

    CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held ® responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. Cleaning Disconnect the instrument from any source of electricity.
  • Page 19: Limited Warranty

    ® If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its ® option, repair or replace the faulty material.
  • Page 20 Notes: Digital Flexprobe Models 400D & 4000D ® ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 21 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...

This manual is also suitable for:

400d-10400d-60400d-1204000d-14

Table of Contents