Identification Of The Unit; Functional Description/Operating Modes - Defensor PH27 Operating Instructions Manual

Adiabatic humidifiers
Hide thumbs Also See for PH27:
Table of Contents

Advertisement

10
3.4

Identification of the unit

The identification of the unit is found on the type plate (for the location of the type plate see unit
overview):
Unit voltage
Admissible water supply pressure
(PH27A only)
Power consumption
Field with certification symbols
3.5

Functional description/Operating modes

Functional description
The fan (1) takes in the air from both sides via the coarse dust filter (2) or the Quattro filter, re-
spectively. After passing the humidification drum, the purified air is led to the outlet lattice () and
distributed in the room.
The unit continuously measures the air humidity in the room with the integrated humidity sensor
and compares it with the set reference humidity value. If the actual value (e.g. 0 %rh) is below the
reference value (e.g.  %rh) the humidification drum (3) starts turning. The vaporizer mat is dipped
into the base tub () and takes up water. The air passing through the humidification drum absorbs
the humidity.
The coarse dust filter retains dust particles up to 100 µm. If the Defensor PH27/PH27A is equipped
with a Quattro filter it can retain dust particles up to 0.1 µm. In addition the activated charcoal layer
in the Quattro filter removes unpleasant odour.
The water level in the base tub is monitored by the level regulating valve in the water tank (Defensor
PH27) or by the level controlled inlet valve (Defensor PH27A).
Type designation
PH27
AC 220...240V / 50...60 Hz
Inlet pressure = 0.5...6 bar
5
1
Serial number
Walter Meier (Climate International) Ltd. 8808 Pfäffikon
XXXXXXX
max. 148 W
Made in Switzerland
2
3
4
Month/Year
11.07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph27a

Table of Contents