Read Simultaneous - RCA 301 Programmer's Reference Manual

Electronic data processing system
Table of Contents

Advertisement

5
Read Simultaneous (RFS)
General Description
This instruction reads a series of consecutive characters from a magnetic card on a 3488 unit starting at the block
previously selected by the Select instruction. The instruction terminates and the transfer of information ends when the
specified HSM area is filled
performed in the Simultaneous Mode.
Format
Operation — 5
N
— Specifies device number.
(60)
8
(64)
A Address — Address of the HSM location that is to receive the first character of the block previously specified by
a Select instruction. Must be an even address.
B Address — Address of the HSM location that is to receive the next to last character read. Must be an even address.
Outline of Operation
If all conditions are acceptable, the read begins when the 3488 unit indicates that the beginning of the selected
block has been reached. The Block Address Register in the 3488 unit counts up with each block read.
If A-B Equality is not obtained by the completion of the read of the last block of the band, the block address
is incremented by one and, if required, the heads are repositioned. When this occurs, the channel will not termi­
nate the instruction. The read continues when the first
Reading of a complete block is not mandatory; A-B Equality can be used to terminate the read whenever desired.
Reads will automatically terminate after block 255.
When A-B Equality is reached, data transfer and the Read instruction are terminated, the Simultaneous Mode
and the channel are freed; however, the 3488 unit remains busy with the read until the interblock gap is reached.
When the interblock gap is reached, the
is executed.
Whether the card stays on or leaves the capstan after a read is terminated is under control of the Select instruc­
tion. If a single bit within a character is missed during a read, the hardware automatically replaces the missing bit, sets
single bit corrected
the
indicator, and continues reading. If more than one bit within a character is missed, (57)
replaces the bad parity character in core memory, the
any subsequent bad parity characters are also replaced by (57)
indicator set, the card remains on the capstan even though the
following the first error character within the same block is not reliable.
When a read is illogically issued following either an
(Select option A
2° = 0) the instruction remains staticized until a card reaches the capstan or the unit goes inoperable.
2
The channel allows only one read (or write) operation at a time. Two channels allow two reads (or writes or
read and write) simultaneously.
If a Read instruction is issued that misses the beginning of its specified block the operation is automatically held
off until the block approaches on the next revolution.
Final Register Contents
(S)
= Address of HSM location one to the right of the last character transferred to memory.
f
(T), = (B),
XV-6
or the last character of block 255 is read, whichever occurs first.
to (63)
on Model 380-14 channel.
8
to (67)
on Model 380-24 channel.
8
8
Test for Read or Write busy
parity error
character of the next block is in position to be read.
indicator is reset and a Block Preselect, if any,
indicator is set and the read operation continues;
's. When a read is terminated with the
8
select
instruction specified its removal. Information
unconditional card removal,
This instruction is
parity error
or a
conditional card removal
s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents