“power density” (W/m²), a certain distance has to be kept from the HF source. For measurements in the lower frequency limits of the HFW59D, the minimum distance between the antenna tip and the object of measurement should be half a meter.
In order to avoid measurement values to be falsified by the often dominant radiation sources from frequencies below, such as DECT or GSM, the HFW59D is equipped with an internal high pass filter at 2.4 GHz, causing these lower frequencies to be sup- pressed.
Page 12
(less than a second) to fully load. Setting: “VBW” For the HFW59D, “VBW Maximum” is the standard setting with which the most common sources of radiation within the meter frequency range, i.e. Radar (a short beep every few seconds) as well as ...
Further Analysis / Optional Accessories: Available from Gigahertz Solutions: For increasing the measurement range of the HFW59D: Preamplifier HV10 for measuring very weak HF signals with a higher resolution. Attenuator DG20_G3 for measuring extra strong HF signals.