Allen-Bradley 1441-PEN25 Release Notes page 8

Enpac 2500 data collector version 3.10
Table of Contents

Advertisement

8 Enpac 2500 Data Collector Version 3.10
Table 3 - Corrected Anomalies with Firmware Revisions 1.03...3.10
Operating
Description
System Version
3.10
CORRECTED: After installing Enpac 2500 data collector revision 3 Hotfix 2, if you collect data on a measurement point and then try to delete the reading, the
instrument errors out TourDBException - cannot find signature tuple. Review the data and delete all the points individually.
CORRECTED: When you load a magnitude/phase measurement point with a collection spec that has more that 8 orders and attempt to load to the collector, it
does not load the measurement point. The error message `Unsupported Measurement' .
CORRECTED: The data collector cannot extract speed from spectrum if magnitude reading is taken first. To avoid this situation, create a Location ID with a
magnitude measurement point prior to a spectrum measurement point.
CORRECTED: When taking a reading with the wrong filter selected, the OA Power Bar does not display when taking a reading.
CORRECTED: Cannot unload multiple readings via USB connection from the Enpac 2500 data collector, revision 3.00 RC7, into the Emonitor software, version
3.40.33 with HF090525.
CORRECTED: While in Route mode, the display listing of alarms and Band alarm status on the instrument needs to be improved.
The tabular listing of alarms are displayed on the Enpac 2500 data collector while in Route mode.
CORRECTED: If you have band alarms that are overlapping then if one is triggered but the overlapping is not, you will not see the whole alarm band flashing
as the untriggered alarm is painted over the triggered one.
CORRECTED: The frequency item order reference is not always the motor speed reference. Although the time waveforms have the correct speed for the motor
locations, the speed increased or reduced locations have an incorrect speed on just the waveforms. The ratio (multiply) relationship is not used, and the
waveform uses the motor speed for its rpm value. This affects only the Enpac 2500 data collector.
CORRECTED: There is no power for accelerometer with velocity output when displaying reading in mils.
CORRECTED: Options for printing to SD and Card is lost. the printing option is available in firmware revision 3.00 RC5 and is not available in firmware revision
3.00 RC7.
CORRECTED: The data collector is unable to support DC Bias Trending in route mode when taking readings from a switch-box. These readings require the
instrument to power the transducer.
CORRECTED: If a store/enter key is pressed before it starts the Initialize process, the unit locks up and must be warm booted. The lock-up unit during Power
Cycle, if Fire key is pressed before Splash Screen has completed.
CORRECTED: Help off Main Menu has orage Ca as the button name.
CORRECTED: The Balancing Extension Module defaults to External Trigger, a LASERTACH® option is needed.
CORRECTED: When a motor is going slow, the rpm on the screen did not display the proper value. When changing speeds, the rpm did not change to match
the motor speed.
CORRECTED: Overall (or Overall and Spec) points can get marked with wrong speed.
CORRECTED: The data collector collects Unfiltered Orbits only, but not 1st Order, 2nd Order, for example, no filtered orbits.
CORRECTED: Having a (Ov+Spec or RSS) Control Point which is it's own reference causes the point to not be taken.
CORRECTED: When a machine is setup in Emonitor and using the Hz as a data collection point, manual entry, issues develops in the Enpac 2500. Amplitude
over time does not work across the screen. It becomes a straight line and the Enpac does not recognize the Hz on the screen.
Rockwell Automation Publication GMSI10-RN004B-EN-E - August 2012
ICM00000823
ICM00000825
ICM00000834
ICM00000845
ICM00000846
ICM00000847
ICM00000848
ICM00000849
ICM00000850
ICM00000861
ICM00000862
ICM00000875
ICM00000877
ICM00000880
ICM00000882
ICM00000924
ICM00000935
ICM00000938
ICM00000940

Advertisement

Table of Contents
loading

This manual is also suitable for:

1441-pen25-z

Table of Contents