The Wavion WBS-2400/5800 is equipped with two RJ45 connectors. The right hand port
named "TEST" is for engineering use only (!) and has to be sealed with the sealing
rubber. Use the ETH port to connect data and power cable.
Figure 4.11
Connecting PoE cable
W
ARNING:
case do not connect PoE source to "TEST" port (!)
Note:
Installation
must be properly terminated and bonded to the unit and to the protective
earth (PE) at the building entrance. This provides protection against the
risk of fire, electrical hazard and ensures the reliable operation of this
equipment.
Note:
Agency Listed (UL/CSA) Building Entrance Protector for all power and
communications cables entering a building. Article 800 is intended to
protect the building and occupants from fires caused by transient voltage
The port named "TEST" is for engineering use only. In any
Use only shielded Cat5e cable rated for outdoor use. See
Accessories on page
32
National Electrical Codes (NEC) Article 800 requires the use of an
for details. The shields of the Cat5 cable