Technical Data; Service; Fan Impeller Replacement; Table 040-1: Fan And Motor Data - Miele T 980x Technical Information

Table of Contents

Advertisement

T 980x/T 982x
1

Technical Data

Motor, fan
Fan, volume flow, free
flowing

Table 040-1: Fan and Motor Data

4

Service

4.1

Fan Impeller Replacement

1. Disconnect the machine from the power supply.
2. Remove the dryer lid; refer to Section 010-4.1.
3. Remove the fascia, the electronic, and the electronic's support panel; refer
to Section 090-4.4.
4. Remove the front panel; refer to Section 010-4.2.
5. Remove the right side panel; refer to Section 010-4.3.
6. Remove the air shield; see Section 050-4.1.
7. Prop up the front of the drum to reduce any strain on the rear bearing.
8. Hold the rear motor shaft (behind the fan) in place with a 13-millimeter
wrench. Loosen the fan impeller bolt by turning it counterclockwise using a
10-millimeter socket (use a ratcheting wrench with an extension to generate
enough torque). See Figure 040-1. Pull the impeller forward to remove.
Vented Dryer
Approx. motor rating 400W
Approx. 200cfm (66' pipe, d = 4", straight-run
without additional structures)
41
Technical Information
Gas Dryer

Hide quick links: