T 980x/T 982x
4.2
Removing the Gas Solenoid
1. Disconnect the machine from the power and gas supplies.
2. Remove the dryer lid; refer to Section 010-4.1.
3. Remove the front panel; refer to Section 010-4.2.
4. Remove the left side panel; refer to Section 010-4.3.
5. Pull the plugs off the gas regulation valve. See Figure 031-7.
Figure 031-7: Gas Regulation Valve
6. Release the connecting line from the gas regulation valve using two
metric 17mm open-end wrenches. With one wrench, loosen the nut on
the gas line, and with the other, maintain counterpressure on the valve.
See Figure 031-8.
35