Miele T 9822 Installation Instructions Manual

Miele clothes dryer user manual
Hide thumbs Also See for T 9822:

Advertisement

Installation Instructions

T 9822 Gas Dryer
en - US, CA
To prevent accidents
and appliance damage
read these instructions
before
installation or use.
M.-Nr. 07 431 110

Advertisement

Table of Contents
loading

Summary of Contents for Miele T 9822

  • Page 1: Installation Instructions

    Installation Instructions T 9822 Gas Dryer en - US, CA To prevent accidents and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110...
  • Page 3 ,WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. Do not store or use gasoline or other flammable – vapors and liquids in the vicinity of this or any other appliance.
  • Page 4: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 5 Installation ............7 Stand .
  • Page 5: Important Safety Instructions

    Installation and connection , WARNING - Risk of Fire When using your gas appliance follow basic safety precautions including the following: It is essential to read all instructions before installing the appliance. To reduce the risk of severe injury or death, follow all installation instructions.
  • Page 6 Product failure due to improper installation is not covered under the Warranty. Gas dryers are not approved for mobile home installation. If there is any doubt concerning installation, contact Miele’s Technical Service Department. 1-800-999-1360 techserv@mieleusa.com 1-800-565-6435 service@miele.ca SAVE THESE...
  • Page 7: Installation

    Front view Exhaust connection Power cord with plug Control panel Door Four height adjustable screw feet Stand A dryer stand, with drawer, can be purchased as an optional accessory. Installation...
  • Page 8 Installation Rear Handle for transportation (arrows) Power cord with plug Slot for module Air intake Gas connection Exhaust connection with restriction insert WARNING : Do not remove the restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions.
  • Page 9: Installation Site

    If the appliance is installed on a raised platform it must be secured with retaining clips available from your dealer or miele. If installed on a masonry or concrete base, the base should have a ½" (13 mm) to 3/4" (19 mm) high rim.
  • Page 10 Installation site Confined space installation ^ When installed in any space with less than 122 square feet (11.3 m minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed. ^ Do not install any other fuel-burning appliance in the same space as the dryer.
  • Page 11: Installation

    Transporting the dryer to the installation site The rear of the lid has a handle for transportation. ^ Use the front dryer feet and the rear of the lid to move the dryer to the installation site. Level the dryer The dryer must be level to ensure safe and proper operation.
  • Page 12: Determining The Position Of The Exhaust Connection

    Installation WARNING Before installation, disconnect the tumble dryer from the electrical supply by shutting off the power main or tripping the circuit breaker. Be sure the dryer power cord is unplugged from the wall. Do not restore power until the installation is complete.
  • Page 13: Electrical Connection

    GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug.
  • Page 14: Gas Connection

    Gas connection WARNING Installation and service must be performed by a qualified installer, service agency or gas supplier. In Massachusetts a licensed plumber / gas fitter is required. This appliance must be installed with its own shut off valve in the same room.
  • Page 15 Make sure that nothing rubs on the gas hose. If there is any doubt concerning installation, contact the Miele Technical Service Department at the phone number listed on the back of this manual.
  • Page 16 Gas connection To secure all connections use appropriate Teflon tape or a thread compound, suitable for gas connections. ^ At the end of the dryer's gas connection hand screw on the " NPT elbow. Using a wrench tighten the elbow with a half turn.
  • Page 17 ^ Using two wrenches tighten the flexible gas line connection. ^ Connect the flare union adapter, to the pressure tapping plug, originally installed on the gas shut off valve, ^ Using two wrenches tighten all connections. DO NOT OVERTIGHTEN. ^ Open the gas shut-off valve. ^ After connecting the appliance check all fittings for gas leaks e.g.
  • Page 18: Ducting

    Ducting Exhaust ducting and connections A gap of " (10 mm) must be provided between the appliance and the floor. This gap is necessary for proper air flow and must not be blocked by a toe-kick or thick piled carpets. Sufficient venting of the installation site is essential for proper dryer operation.
  • Page 19: How To Calculate The Effective Duct Length

    How to calculate the effective duct length The overall duct length will determine the duct diameter (see the "Additional duct lengths" table). In Canada the exhaust duct must be 4" (102 mm) in diameter. ^ Measure the actual duct length needed to go from the dryer’s exhaust connection to the vent outlet: 1.
  • Page 20 Ducting Tips about the ductwork – Check with your local building code to determine the maximum allowable duct length. – Only use rigid or flexible metal duct for exhausting. Non-metallic flexible hose should not be used, it is a potential fire hazard. –...
  • Page 21 Additional duct lengths (4" [100 mm] rigid pipe only) Type of bend Flexible metal duct – 3’ 3" (1 m) straight – 45° angle – 90° angle Smooth metal duct – 3’ 3" (1 m) straight – 45° angle – 90° angle Elbow 90°...
  • Page 22 Ducting Example Rigid pipe Wall duct with louvered wall vent 90° bend 20" (0.5 m) rigid pipe 90° bend left / right vent opening Total duct length The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm) with adapter is sufficient.
  • Page 23: Exhaust Connection With A Flexible Exhaust Hose Or Rigid Pipe

    (4" [100 mm] diameter) can be installed. Necessary materials: – a wall or window duct (available from Miele) – an exhaust hose made of approved non-flammable material ^ Install the required adapter* 1 with the exhaust hose or pipe 2 to the dryer.
  • Page 24 2 and connect the pipe 3. Window connection (example) 1 Window duct 2 Connector for the rigid or flexible exhaust hose Wall connection (example) 1 Wall pipe (Installation sheet supplied with the Miele wall pipe) 2 Connector 3 Rigid pipe...
  • Page 25: Direct Wall Connection

    Direct wall connection Necessary materials: – a wall pipe – flexible foam gasket Dryer top view 1 Wall pipe 2 Flexible foam gasket Dryer side view 1 Wall pipe 2 Flexible foam gasket ^ Only required with side exhaust vent connection (left or right) : Plug the restriction insert 1 into the wall pipe.
  • Page 26: Caring For The Environment

    Caring for the environment Disposal of the packing materials The packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. To prevent suffocation, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
  • Page 28 Alteration rights reserved / 1612 M.-Nr. 07 431 110 / 04 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.

This manual is also suitable for:

Touchtronic t 9822

Table of Contents