T 980x/T 982x
4. For the permanent assembly, give the connecting nut another quarter-
turn with a metric 17mm open-end wrench (19 Nm ± 1 Nm) while
maintaining counterpressure on the double nipple with a second metric
17mm open-end wrench. See Figure 031-10.
Figure 031-10: Tightening the Gas Regulation Valve
5. Connect the 2 plugs and the ground lead to the gas regulation valve. See
Figure 031-11.
Figure 031-11: Gas Regulation Valve
37