Operational parameters. Pressure fluids
In order to ensure the functional performance and high efficiency of the hydraulic pumps the viscosity and purity of the operating
fluid should meet the different operational requirements. Linde recommends using only hydraulic fluids which are confirmed by
the manufacturer as suitable for use in high pressure hydraulic installations or approved by the original equipment manufacturer.
Permitted pressure fluids
>>
Mineral oil HLP to DIN 51524-2
>>
Biodegradable fluids in accordance with ISO 15380 on request
>>
Other pressure fluids on request
Linde offers an oil testing service in accordance with VDMA 24 570 and the test apparatus required for in-house testing. Prices
available on request.
Recommended viscosity ranges
Pressure fluid temperature range
Working viscosity range
Optimum working viscosity
Max. viscosity (short time start up)
In order to be able to select the right hydraulic fluid it is necessary to know the working temperature in the hydraulic circuit. The
hydraulic fluid should be selected such that its optimum viscosity is within the working temperature range (see tables).
The temperature should not exceed 90 °C in any part of the system. Due to pressure and speed influences the leakage fluid tem-
perature is always higher than the circuit temperature. Please contact Linde if the stated conditions cannot be met or in special
circumstances.
Viscosity recommendations
Working temperature [°C]
approx. 30 to 40
approx. 40 to 60
approx. 60 to 80
8
[°C]
[mm ² /s] = [cSt]
[mm ² /s] = [cSt]
[mm ² /s] = [cSt]
Viscosity [mm ² /s] = [cSt] at 40 °C
22
32
46 or 68
-20 to +90
10 to 80
15 to 30
1000