Controllers. E1L. Load Sensing with electric override
In addition to the load sensing function, the HPR-02 E1L offers an electric override for mode selection and power limit regulation
02
03
04
(underspeed control). The integration of all functions in the pump controller enables direct signal transfer without delays. The
controller-specific data are independent of the nominal pump size.
A
P1
P
In the event of an electric override of the LS-signal, a pressure reducing valve is activated via the proportional solenoid. The
control pressure generated in this way acts proportionally against the LS-spring, and the effect of the ∆p LS signal is modulated
accordingly. This causes the pump to swash back, thereby reducing its output. The function between control current (l) at the
control solenoid and the associated ∆p LS value is shown in the diagram. At the port "A", the control pressure can be picked up and
forwarded to an H1L controller at another HPR pump, which follows the first pump with the E1L controller (master-slave-operation).
02
03
04
In case of a malfunction in the electric control, a control pressure can be fed to the E1L controller at the port "X1" to reduce the
∆p LS setting and therefore keep the application operational.
∆p LS-reduction
4
3
2
1
16 bar ∆p setting
1
20 bar ∆p setting
2
25 bar ∆p setting
3
28 bar ∆p setting
4
24
05
06
E1L
D1
P
A
X
T
0
max
T
U
L
05
06
control current [mA] at 24V
control current [mA] at 12V
07
08
09
X1
LS2
LS1
X
Projekt-Name:
Projekt-Titel:
Dokument-Name:
Dokument-Titel:
Projekt-Ersteller:
Dokument-Ersteller:
Erstellt am:
Zuletzt gespeichert:
07
08
09
E1L-controller
10
11
01
02
03
04
05
06
07
HPR-02-A2-E1L0_Schaltplan_Katalog_v01
Schaltplan_E1L
08
RA3 - P.Schlee
RA3 - P.Schlee
16.03.2012 15:03:58
16.03.2012 15:17:10
10
11

Advertisement

Table of Contents
loading

Table of Contents