Philips MRV640 Service Manual page 60

Dvd-video recorder
Table of Contents

Advertisement

EN 60
5.
DVDR615, MRV640
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
User Input
Example
Diagnostic Software
-
Evaluate user input.
-
Set-up IIC-bus.
-
Write data to boot EEPROM.
-
Update checksum.
1 second
A large hexadecimal value that represents the digital board settings obtained from
the DbString.exe program or from a reference set.
Number
Description
122600
The settings were successfully programmed.
122601
User input is invalid.
122602
IIC access failed.
DS:> 1226 646961677473746201010200010101010101000020080000
122600:
Test OK @
DS_SYS_SettingsSetup
1227
Investigates the system by means of partial auto-detection. After that it programs the
settings into the boot EEPROM on the digital board.
The nucleus asks the user some questions, and the user can response them with de-
fined answers.
DS:> 1227
Investigating the system, please wait...
Enter a name for the digital board:
>my board
Enter the HW ID of the digital board [Default = 0]
>0
Wich type of Codec IC is present [Default = 2]
0. None
1. PNX7100_MF1
2. PNX7100_MF2
3. PNX7100_MF3
>2
Wich type of VIP IC is present [Default = 3]
0. None
1. SAA7114
2. SAA7115
3. SAA7118
4. SAA7119
>3
Wich progressive scan DeInterlacer is present [Default = 0]
0. None
1. FLI1200
2. FLI2200
3. S2301
>0
Wich progressive scan denc is present [Default = 1]
0. None
1. ADV7196
>1
Wich 1394 physicallayer IC is present [Default = 1]
0. None
1. PDI1394P2540
>1
Wich 1394 linklayer IC is present [Default = 1]
0. None
1. PDI1394L40
>1
Wich audio clock scheme is used [Default = 2]
0. None
1. Audio clock scheme 0
2. Audio clock scheme 1
3. Audio clock scheme 2
>2
Is the Basic engine (AV1.x/2.x) connector available [Default = 'Y']
>Y
Is IDE connector 1 available [Default = 'Y']
>Y
Is IDE connector 2 available [Default = 'N']
>N

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvdr615/17Dvdr615Mrv640/17

Table of Contents