Philips MRV640 Service Manual page 54

Dvd-video recorder
Table of Contents

Advertisement

EN 54
5.
DVDR615, MRV640
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Diagnostic Software
DS:> 1207 1234567890
120700:
Test OK @
DS_SYS_DvIdNumberGet
1208
Get the IEEE1394 ID
-
Read out the ID from the configuration segment and return this info to the user
Less than 1 second.
None
Number
Description
120800
Getting the unique DV ID succeeded
120801
Getting the unique DV ID failed
DS:> 1208
120800: The DvIdNumber is: 0x0C22384E5A
Test OK @
DS_SYS_IicWrite
1209
Perform an IIC write action on the digital board
-
Determine bus ID, slave address, number of bytes to be written and the byte
array of data from the user input
-
Initialise IIC
-
Write the data to the slave specified through IIC
Less than 1 second
The user input the number of bytes to write followed by these bytes:
<BusID><Slave address to write to><number of bytes to write><d1><d2><..><dx>
Where the bus ID is either 0 (normally used) or 1
Number
Description
120900
Writing the data over IIC succeeded
120901
The IIC bus was not accessible
120902
There was a timeout writing to the device
120903
The IIC acknowledge was not received
120904
The communication with the device failed
120905
Got unknown IIC bus error:
120906
Unable to initialise IIC bus
120907
Decoding bus ID unsigned value failed
120908
Decoding slaveAddr unsigned value failed
120909
Decoding nrBytes unsigned value failed
120910
Bus ID out of range
120911
nrBytes out of range
120912
Unable to decode parameters
DS:> 1209 0 0xa0 1 0x6
120900: 1 Bytes written
Test OK @
DS_SYS_IicRead
1210
Perform an IIC read action on the digital board
-
Determine the bus ID, slave address and number of bytes to read from the
user input
-
Initialise IIC
-
Read the data form the slave specified
Less than 1 second
The user inputs the number of bytes to read and the address to read them from:
<BusID><Slave address to read from><Number of bytes to read>
Where the bus ID is either 0 (normally used) or 1
Number
Description
121000
Reading the data over IIC succeeded
121001
The IIC bus was not accessible
121002
There was a timeout writing to the device
121003
The IIC acknowledge was not received
121004
The communication with the device failed
121005
There was an unknown IIC bus error