Philips MRV640 Service Manual page 30

Dvd-video recorder
Table of Contents

Advertisement

EN 30
5.
DVDR615, MRV640
Error
Example
Progressive Scan (PSCAN)
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Execution Time
User Input
Error
Example
Nucleus Name
Nucleus Number
Description
Technical
Diagnostic Software
Number
Description
70600
The stream was detected
70601
The 1394 link chip could not be initialised properly
70602
No stream detected
DS:> 706
070600:
Test OK @
DS_PSCAN_CommunicationDenc
801
Check the communication between the IIC controller of the chrysalis and the progressive
scan DENC-IC
-
Initialise IIC
-
Write data to a register of the DENC through IIC
Less than 1 second
None
Number
Description
80100
Communicating with the progressive scan DENC-IC succeed-
ed
80101
The IIC bus was not accessible
80102
There was a timeout reading the device
80103
The IIC acknowledge was not received
80104
Communicating with the progressive scan DENC-IC failed
80105
The initialisation of the IIC bus failed
80106
The read data is not the same as the written data
80107
No chip was expected
DS:> 801
080100:
Test OK @
DS_PSCAN_TestImageOn
802
Generate the test images that are present on the progressive scan IC.
-
See whether the user wanted a HATCH or a FRAME image pattern
-
Initialise the PIO pins of the chrysalis
-
Initialise IIC
-
Reset the DENC
-
Enable the 27Mhz clock
-
Send all settings for the pattern to the DENC through IIC
Less than 1 second
In case of ADV7196:
When no input is given "HATCH" is the default
-"HATCH"
-"FRAME"
Remark:
"HATCH" is a crosshatch test pattern (horizontal and vertical white lines are displayed
against a black background)
"FRAME" is a uniform coloured frame/field test pattern (default white).
In case of FLI2300: Nothing.
Number
Description
80200
The generation of the test image succeeded
80201
Unable to initialise pscan ic
80202
Unable to reset DENC
80203
Unable to generate image
80204
No chip was expected
DS:> 802 HATCH
080200:
Test OK @
DS_PSCAN_TestImageOff
803
Switch off the generated test image
-
Initialise IIC
-
Send the default DENC settings to the DENC through IIC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvdr615/17Dvdr615Mrv640/17

Table of Contents