User Input
None
Error
Number
100100
100101
100102
100103
100104
Example
DS:> 1001
100100: DCB version: 13
Test OK @
Nucleus Name
DS_DCB_LightDisplay
Nucleus Number
1002
Description
Light the entire display of the DCB, and clear the display after confirmation.
User confirmation is necessary.
Technical
- First issue a command to clear the display and wait for the result
- Then issue the command to light the entire display and wait for confirmation by the
user
Execution Time
Until user confirmation.
User Input
None
Error
Number
100200
100201
100202
100203
100204
100205
100206
100207
100208
100209
Example
DS:> 1002
100200:
Test OK @
Nucleus Name
DS_DCB_Keyboard
Nucleus Number
1004
Description
Check all keys of the keyboard by confirming the key-code displayed of each key.
Technical
- Initialise the display
- Display the key pressed by the user on the display
- Monitor the service port for an abort and get the next key pressed
- Update the display and repeat previous steps until user stops / confirms
Execution Time
Until user confirmation. Confirm by press & hold respective button
User Input
None
Error
Number
100400
100401
100402
100403
100404
Example
DS:> 1004
100400:
Test OK @
Nucleus Name
DS_DCB_RemoteControl
Nucleus Number
1005
Description
Check the interface between the remote control and the DCB by checking the key-
code displayed
Technical
-
-
-
-
Diagnostic Software
Description
Retrieving the version of the DCB succeeded
The DCB could not be accessed by the analogue board.
There was no response from the analogue board.
The returned errorcode from the analogue board is un-
known
Something went wrong with the error code.
Description
Lighting the entire display succeeded
The DCB could not be accessed by the analogue board.
There was no response from the analogue board.
The returned errorcode from the analogue board is un-
known
The DCB could not be accessed by the analogue board.
There was no response from the analogue board.
The DCB did not light all labels.
The user skipped the rest of the DCB_Light_Display test.
The user returned an unknown confirmation:
The returned errorcode from the analogue board is un-
known
Description
All the keys on the keyboard have been pressed
DCB Keyboard; test failed
DCB Keyboard; test aborted
Not all the keys were pressed.
The DCB could not be accessed by the analogue board.
Initialise the display
Display the key pressed by the user on the display
Monitor the service port for an abort and get the next key pressed
Update the display and repeat previous steps until user stops / confirms