Resetting the module to its factory defaults

You can return a module to its factory default by the system default command.
This command returns all parameters to its factory defaults.
Command:
Example:
Output:
Note: To return the entire switch to its factory defaults, type system default on
each of the modules and afterwards perform a reset to the entire switch.

Rebooting the module or switch

It is highly recommended that you use the
module in the M770 ATM Switch or the entire switch, instead of using the reset button.
This is because the
configuration updates to the non-volatile memory, whereas pressing the reset button
may cause configuration information to be lost.
To reboot the module or switch, use the
You will be prompted to confirm the operation.
Command:
Parameters:
Example:
Output:
Note: When the M770 ATM Switch is rebooted, all connections will be lost.
Cajun M770 ATM Switch User's Guide
M15-155s8:/>system default
M15-155s8:/>system default
WARNING: This command will erase the entire module
configuration. All current parameters will be lost and
replaced by the factory defaults
NOTE: Changes will take effect only after a module reset.
Do you want to continue (Y/N)?y
command first flushes any outstanding
system reboot
system reboot [module|switch]
M15-155s8:/>system reboot [module|switch]
The module will be restarted, losing all connections
module
to the module.
The switch will be restarted, losing all connections to
switch
the switch.
M15-155s8:/>system reboot module
This will restart the module, losing all connections -
do you want to continue (y/n)?
Chapter 17
Managing System Commands
command to reboot a
system reboot
command.