Warning; Communication Errors; Winder Timeout - Seiko I Infotech IP-6600 Maintenance Manual

Color ink jet printer
Table of Contents

Advertisement

5.4

Warning

5.4.1

Communication errors

A communication error indicates that there is a problem in communication conditions or
protocol with the SCSI connection between the printer and the computer.
PRINT READY
W SCSI ERROR nnn
Parity error
Bus timeout error
<Measures>
5.4.2

Winder timeout

The winder slack sensor is kept ON and paper is not wound.
<Measures>
5-10
Error description
(1)
Check SCSI cable connection and terminator switch.
(2)
Turn the host SCSI parity bit setting ON.
(3)
Check the host SCSI driver setting.
(4)
Replace WIM1 board.
The error LED flashes.
(1)
Remove the paper at the slack sensor.
(2)
Place paper on the winding paper core correctly.
nnn: Error code
Error state display
W SCSI ERROR 001
W SCSI ERROR 002