Fcc And Industry Canada Compliance; Compliance Statement (Part 15.19); Warning (Part 15.21); Rf Radiation Safety Guidelines Per Part 2 Of Fcc Rules And Regulations - Elster A3 ALPHA Product Manual

Meter/collector
Hide thumbs Also See for A3 ALPHA:
Table of Contents

Advertisement

July 2004
Table 4. Max. number of days of storage available per interval
FCC and Industry
Canada Compliance
REX meters allowed to register
Load profiling interval: 15 minutes
35
70
100
250
500
1024
Load profiling interval: 30 minutes
70
100
250
500
1024
Load profiling interval: 60 minutes
70
140
250
500
1024

Compliance Statement (Part 15.19)

The A3 ALPHA meter/collector complies with Part 15 of the FCC Rules and with
RSS-210 of Industry Canada. Operation is subject to the following two condi-
tions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interfer-
ence that may cause undesired operation.

Warning (Part 15.21)

Changes or modifications not expressly approved by Elster Electricity, LLC could
void the user's authority to operate the equipment.
RF Radiation Safety Guidelines per Part 2 of FCC Rules
and Regulations
The meter should be installed in a location where there will be a separation
greater than 20 cm (8 inches) from locations occupied by humans.

User Information (Part 15.105)

The A3 ALPHA meter/collector has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
A3 ALPHA Meter/Collector
Product Guide
Days of LP storage
Collection time: every 4 hours
54
27
18
7
3
1
Collection time: every 6 hours
50
35
13
5
1
Collection time: every 12 hours
101
49
26
11
3
11

Hide quick links:

Advertisement

Table of Contents
loading