Error Code
Error Name
082+084
Fatal system Failure
(RAP=082,
AP=084)
088
JB No Connection
094
Backup HDD
Recording Fail
098
DRU Recording Fail
170
VDR Configuration
Fail
171
VDR Recording
Buffer Overflow
173
Fatal System Failure
174
IEEE1394 Bus
Recover Giveup
186
DRU Memory
Shortage
214
Battery Running
218
MIC Test Fail
226
DRU Flash Device
No match
234
GPS No Connection
Description
Fatal system error. This indicates
that VR-3000/S can not be rebooted
automatically.
Indicates that Junction Box (No.1) is
missing.
Indicates that Backup is inactive-not
storing data.
Indicates that DRU is inactive-not
storing data.
Data can not be stored because
VDR setting data is corrupted.
Radar video inputs over the capacity
of the recording buffer memory.
Fatal system error. VR-3000/S
rebooted automatically after an error
occurred.
Cannot Recover DRU and Backup
HDD
It looks that data can not be
recorded more than 12 hours.
Both AC and DC power are down
and switching to battery drive.
Audible alarms are generated for
max. two.
This ALARM is issued when the
microphone test fails. This test can
be run from Audio tab in the VDR
Maintenance Viewer, and is run
every 12-hours during normal
operation.
This indicates that no. of FLASH
device found in DRU and defined
in CONFIGURATION is not same.
System does not receive UTC
information.
Action
Reboot VR-3000/S manually. If VR-3000/S
does not recover, request service.
Note: After switching to battery drive (error
code 214), this error may occur. The error
disappears and the system recovers after
AC and/or DC power is reconnected.
Check cable and IP-address setting.
Check connection to Backup HDD. If not
still storing, request service.
Check connection to DRU. If not still
restarting recording, request service.
Restore VDR setting data. If not, request
service.
Check or reduce the radar channels or
video resolutions.
If VR-3000/S repeat continuously, request
service.
Restart VDR. If VR-3000/S does not
recover, request service.
Modify radar recording setting. Max.
recordable channel: two channels.
Reconnect AC and/or DC power.
Check MIC TEST in the VDR Maintenance
Viewer. If this is OK, locate the faulty
microphone and check/replace it.
Check if no. of FLASH devices and
configuration setting are same.
Check that a valid UTC source is
connected to the serial port defined as UTC
source.
19