Extech Instruments MA440 User Manual page 2

400a ac clamp meter dmm
Hide thumbs Also See for MA440:
Table of Contents

Advertisement

Introduction 
Thank you for selecting the Extech EX44x Series 400A Clamp Meter. 
 
The MA440 is a 400A AC Clamp meter with a total of 9 functions. 
 
The MA443 is a 400A True RMS AC Clamp meter that offers 10 functions including TRMS AC 
measurements and Type K Thermocouple 
 
The MA445 is a 400A AC/DC True RMS Clamp meter with 11 functions including DC Current, TRMS 
AC measurements, and Type K Thermocouple. 
 
The MA44x series are hand‐held, 4000 count clamp meters. This meter series measures AC/DC 
voltage, AC current, DC current (MA445), resistance, diode, continuity, capacitance, temperature 
(MA443 and MA445), frequency, and duty cycle. In addition, these meters offer Display hold, MIN‐
MAX (MA443 and MA445), Relative mode, NCV (non‐contact voltage detection), and automatic 
power OFF. 
 
In addition to the meter, the packaging includes Instructional documentation (Quick Start), Test 
Leads, K‐type temperature probe (MA443 and MA445), batteries, and a pouch. 
 
This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable 
service. Please visit our website (www.extech.com) to check for the latest version of this User 
Guide, Product Updates, Product Registration, and Customer Support. 
Safety 
To ensure the safe operation and service of the meter, follow these instructions closely. Failure to observe 
warnings can result in severe personal injury or death. 
These instruments are designed and produced in strict accordance with IEC/EN61010‐1, IEC/EN 61010‐2‐032, 
and IEC/EN 61010‐2‐033, safety standards, and comply with the safety standard for double insulation, 
overvoltage CAT III 600V and pollution level 2.  Please observe all operational and safety instructions 
otherwise the protection provided by instrument may be compromised. 
These instruments conform to UL standard 61010‐1, 61010‐2‐032, 61010‐2‐033; these instruments are 
certified to CSA standard C22.2 no. 61010‐1, IEC standard 61010‐2‐032, and IEC standard 61010‐2‐033. 
CAT III: Applicable to test and measuring circuits connected to the distribution section of a building's low 
voltage mains installation; before use of these instruments please observe and obey all safety instructions. 
 
 
 
 
 
 
 