SiBE12-713
Be sure the air conditioner is electrically grounded.
Do not connect the grounding conductor to a gas pipe,
water pipe, lightning arrester, and the grounding conduc-
tor for a telephone.
Imperfect grounding work may result in an electric shock.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by
young children or infirm persons without
supervision.
Young children should be supervised to
ensure that they do not play with the appliance.

3. OPERATION RANGE

If the temperature or the humidity is beyond the following con-
ditions, safety devices may work and the air conditioner may not
operate, or sometimes, water may drop from the indoor unit.
COOLING
OUTDOOR UNIT
TEMPER-
ATURE
DB 18 to 33 80% or
R35 · 45 · 60
WB 12 to 24
DB 18 to 33 80% or
RY35 · 45 · 60
WB 12 to 24
R71 · 100 · 125
DB 21 to 35 80% or
RP71 · 100 · 125
WB 14 to 25
REP71 · 100 · 125
RY71 · 100 · 125
DB 18 to 35 80% or
RYP71 · 100 · 125
WB 12 to 25
RYEP71 · 100 · 125
DB 21 to 35 80% or
RZP71 · 100 · 125
WB 14 to 25
DB 18 to 37 80% or
RQ71 · 100 · 125
WB 12 to 28
DB 18 to 37 80% or
RR71 · 100 · 125
WB 12 to 28
DB 18 to 37 80% or
RZQ71 · 100 · 125 ·
140
WB 12 to 28
RS50 · 60
DB 21 to 32 80% or
RKS35 · 50 · 60
WB 14 to 23
RXS35 · 50 · 60
3MKS50
DB 21 to 32
4MKS58 · 75 · 90
3MXS52 · 2MXS52
WB 14 to 23
4MXS68 · 80
DB 21 to 32 80% or
RMKS112 · 140 · 160
RMXS112 · 140 · 160
WB 14 to 23
Operation Manual
INDOOR
OUTDOOR
TEMPERA-
HUMID-
TURE
ITY
DB – 15 to 46
below
DB – 5 to 46
below
DB – 15 to 46
below
DB – 5 to 46
below
DB – 5 to 50
below
DB – 5 to 46
below
DB – 15 to 46
below
DB – 15 to 50
below
DB – 10 to 46
below
80% or
DB – 10 to 46
below
DB – 5 to 46
below
HEATING
INDOOR
OUTDOOR UNIT
TEMPERATURE
RY35 · 45 · 60
DB
15 to 27
RY71 · 100 · 125
RYP71 · 100 · 125
DB
15 to 27
RYEP71 · 100 · 125
RZP71 · 100 · 125
DB
15 to 27
RQ71 · 100 · 125
DB
10 to 27
RZQ71 · 100 · 125 ·
DB
10 to 27
140
RXS35 · 50 · 60
DB
10 to 30
3MXS52 · 2MXS52
DB
10 to 30
4MXS68 · 80
RMXS112 · 140 · 160 DB
10 to 30
D B: Dry bulb temperature (˚C)
WB: Wet bulb temperature (˚C)
The setting temperature range of the remote con-
troller is 16˚C to 32˚C.
4. INSTALLATION SITE
Regarding places for installation
• Is the air conditioner installed at a well-venti-
lated place where there are no obstacles
around?
• Do not use the air conditioner in the following
places.
a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring
resort
d.Where there are considerable voltage fluctua-
tions such as a factory or plant
e.Vehicles and vessels
f .Where there is much spray of oil and vapor such
as a cookery, etc.
g.Where there are machines generating electro-
magnetic waves
h.Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
Instruction
OUTDOOR
TEMPERATURE
DB
– 9 to 21
WB – 10 to 15.5
DB
– 9 to 21
WB – 10 to 15.5
DB
– 14 to 21
WB – 15 to 15.5
DB
– 9 to 21
WB – 10 to 15
DB
– 19.5 to 21
WB – 20 to 15.5
DB
– 14 to 24
WB – 15 to 18
DB
– 14 to 21
WB – 15 to 15.5
DB
– 14 to 21
WB – 15 to 15.5
215