If the Iridium Edge needs to be removed, do not pry it off the asset. Prying can damage both Iridium
Edge or the mounting surface. It is recommended to remove Iridium Edge using a thin wire that is sawed
back and forth under Iridium Edge to cut the double sided tape.

5.7 Mating Cable Installation

Once a mounting location is determined, use the guidelines below when installing the cable:
Verify and follow all local electrical codes
Identify a DC power source that complies with the input voltage and maximum current
specification of the Iridium Edge listed on the label. Never connect the Iridium Edge to an AC
power source.
Only use cables provided from an Iridium Service Provider that meet cable the specifications
listed in Section 4 Mating Cable Guidelines on page 44 .
CAUTION Use power and ground conductors of proper gauge. Use of improper
gauge power cables could result in exposing cables to excessive heat which could
cause fire, resulting in serious injury or death.
Ensure that the device is not routed near exhaust pipes or other hot surfaces.
Do not bend the cable excessively around sharp corners so as to violate its bend radius
specification provided by the Service Provider.
Route or protect the cable to avoid damages against persons walking or tripping.
The cable must be securely connected to the power supply return ground, close to the power
source. The ground connection must be connected prior to connecting power to the device.