9 WHEN COMMUNICATING DATA USING THE MC PROTOCOL

9.3.3 Batch write in bit units (command: 02)

[Control procedure]
(Data name)
External device
side
(Example)
(Data name)
PLC side
(Example)
9 - 21
The examples shown in this section explain the command/response format when batch
writing to the bit device memory.
For more details on the order and contents of data items of the areas marked by " "
shown in the control procedure diagram, see Section 9.1.2.
Writing the on/off status of M50 to M61 of the PLC on which the Ethernet module is
loaded.
(1) Communication in binary code
Head device
L
H
L
-
-
02
FF
0A
00
32H 00
00
H
H
H
H
H
0
1
M51
(ON)
M50
M52
(ON)
(OFF)
Data for the number
of designed device
points
Characters for the
number of device
points
-
-
H
L
H
L
00
20
4D
0C
00
01
11
01
00
H
H
H
H
H
H
H
H
H
1
1
0
1
0
0
0
0
0
M53
M55
M57
M59
(ON)
(ON)
(OFF)
(OFF)
M54
M56
M58
M60
(OFF)
(OFF)
(OFF)
(OFF)
H
L
H
00
01
H
H
H
82
00
H
H
1
M61
(ON)