9、Comm Operation:The user can use or test voice and com port
transmission functions in this page.
1.
communication parameters in this page. The parameters are
effective in current connection, but it will not change the
system settings.
a. Quality:2~10
b. Local Port:RS232/RS485/VxComm
c. Remote Port:RS232/RS485/VxComm
d. Baud Rate:1200 / 2400 / 4800 / 9600 / 19200 / 38400 /
e. Data Bits:5 / 6 / 7 / 8 data bits
f. Parity:None / Odd / Even / Space
g. Stop Bits:1 / 2 stop bits
h. Flow Control:None / Hardware / XonXoff
i. GetStatus : The user can get current communication
j. SetStatus : The user can set current communication
2. Operation:The settings will only show in page of the server.
If you want to refresh the status in this page, you can click
M-4132 User Manual (Version 1.60, May/2014)
Communication
Select the audio quality.
Select local com port connection from RS-232 or RS-485
or VxComm.
Select remote com port connection from RS-232 or RS-
485 or VxComm. This setting is used for VSoIP_Server.
57600 / 115200 / 230400 bps
Select baud rate of com port.
Select data bits of com port.
Select parity of com port.
Select stop bits of com port.
Select flow control of com port.
parameters from this button.
parameters from this button.
configure : The
user
can
select