D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
6.
Press [ENTER] to save the programming.
7.
When the keypad shows Repeater Replaced, escape from the menu.
B93x/B94x keypads Configuration of Replace Repeater
1.
Enter the installer passcode, and then open the [1] Installer menu.
2.
Go to the [2] Wireless > [2] Repeaters > [2] Replace Repeater menu option.
3.
Press [PREV]/
you wish to replace, or simply enter the repeater number.
4.
Press the Enter softkey to replace repeater points. The keypad instructs you to reset the new
device.
5.
Initiate activity for the desired RADION device per the device instructions, or press the
[RESET] button on an Inovonics device
6.
When the keypad shows Repeater Replaced, escape from the menu.
18.2.6 [2] Repeaters > [2] Remove Repeater Menu Parameters
In this menu, you can remove repeater points.
Remove Repeater
B91x/B92x keypads Configuration of Remove Repeater
1.
Enter the installer passcode, and then open the [1] Installer menu.
2.
Go to the [2] Wireless > [2] Repeaters > [3] Remove Repeater menu option.
3.
Press [PREV] or [NEXT] to scroll through the list of repeaters, and go to the repeater you wish
to remove, or simply enter the repeater number.
4.
Press [ENTER] to remove the device. The keypad removes the device and shows Repeater
Removed.
5.
Escape from the menu.
B93x/B94x keypads Configuration of Remove Repeater
1.
Enter the installer passcode, and then open the [1] Installer menu.
2.
Go to the [2] Wireless > [2] Repeaters > [3] Remove Repeater menu option.
3.
Press [PREV]/
you wish to remove, or simply enter the repeater number.
4.
Press the Remove softkey to remove the repeater. The keypad removes the device and shows
Repeater Removed.
5.
Escape from the menu.
18.2.7 [3] Diagnostics > [1] RF Points
You can obtain wireless point diagnostic information using a keypad and this menu.
States (for RF points)
B91x/B92x keypads use of States (for RF points)
1.
Enter the installer passcode, and then open the [1] Installer menu.
2.
Go to the [2] Wireless > [3] Diagnostics > [1] RF Points menu option. The keypad toggles
between showing the option for state and the option for signal strength for the selected point.
3.
Press [PREV] or [NEXT] to scroll through the list, and go to the point for which you wish to
view diagnostic information, or enter the point number.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09
or [NEXT]/
to scroll through the list of repeaters, and go to the repeater
or [NEXT]/
to scroll through the list of repeaters, and go to the repeater