Adjustment Of The Installation Position Of The Shutter Drive Gear Of Fs-114 - Konica Minolta 7145 Service Manual

Hide thumbs Also See for 7145:
Table of Contents

Advertisement

7145 series Field Service Ver.4.0 Mar. 2004
• 2-Point Staple
Measurement
Specification
position
C, F
6.0 ± 4mm
D
Y ± 4mm
E
X ± 4mm
Y = (paper width-x-11) / 2
X = A3, A4: 137
B4, B5: 114
A4R: 190
B5R: 162
Substitute above into the equation.
3. If the staple position is misaligned, remove one
screw and the cover.
4. Loosen two adjustment screws and move the
Stapler Unit in the direction of the arrow to make
the adjustment.
5. Make another copy and check the staple posi-
tion.
10.15Adjustment of the Installa-
tion Position of the Shutter
Drive Gear of FS-114
• When the gear/1, 2 or 3 is replaced, or the gear/
1, 2 or 3 is removed.
A. Procedure
1. Set three gears.
Note:
• Set the gears so that the marks on Gears 1 and 3
are aligned with the rib of Gear 2 as shown on the
right.
Adjustment range
+1mm to -2mm
1-109
OTHER ADJUSTMENTS
C
D
E
F
Gear 2
Gear 1
4349D505AA
4349D513AA
Gear 3
4349D502AA
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

723572287222