Content
Device abnormality
The unit did not start up nor-
001
mally.
Failed writing to internal flash
003
ROM.
005
MAC address was lost.
Settings saved in internal
017
memory were lost.
040
The IP address conflicts.
The IP address was not estab-
041
lished within 60 seconds after
startup.
The devices making up the
042
MTX/MRX system were not
found on the network.
Too many devices are con-
043
nected to the network.
A device with the same UNIT
ID was found among the
051
devices connected to the same
network.
060
Failed to recall a preset.
The preset could not be
064
recalled.
Action
Turn off the power supply of the
PSE, wait at least six seconds,
and then turn on the power. If
this does not solve the problem,
initialize the MCP1.
Perform synchronization again
using MTX-MRX Editor.
Make settings so that the IP
address does not conflict.
If the IP Setting is set to "PC,"
use MTX-MRX Editor or the
DHCP server to specify the IP
address.
Power-on all devices making up
the system, and make sure that
they are correctly connected to
the network.
Reduce the number of devices
connected to the network.
Make settings so that the UNIT
ID does not conflict.
Initialize the MCP1.
The Preset selected for recall
cannot be recalled as no data
has been stored to it, or another
device may have been added
after presets were stored.
Please synchronize and check
all presets using MTX-MRX
Editor, and store again.
Single /
Type
Continuing
Fault
Continuing
Fault
Continuing
Fault
Continuing
Fault
Continuing
Error
Continuing
Warning
Continuing
Error
Continuing
Error
Single
Error
Continuing
Error
Continuing
Warning
Continuing