Reference Conditions: 41°F ± 5°F (23°C ± 3°C), 20 to 70% RH, 50Hz, 1 minute warm-up, battery at
9V ± 0.1V, external magnetic field < 40A/m, no DC component, no external current carrying conduc-
tor, 10MΩ load, conductor center.
3.1

Electrical

Current Range: 300/3000A
Output Signal: mV output (4000mV peak max)
Three position slide switch: 10mV/A 5A to 300Arms
AC Current Accuracy (after calibration and for one year):
1% of Reading ± 500mA
Crest Factor: 4.5
Phase Shift: < 0.7° at 50 or 60Hz
Frequency Range: 40 to 5kHz
Residual Noise When I Measured = 0: 200mArms
Working Voltage: 1000Vrms CAT III; 600V CAT IV
Common Mode Voltage: 600Vrms max
Influence of Frequency: Add 1% to the reference accuracy between 40
and 2000Hz, and up to 5% at 5kHz
Influence of Adjacent Conductor: <2%
Influence of Conductor Position in Jaw: <4%
Power Source: 9V alkaline (NEDA 1604A, IEC 6LR61)
Battery Life: 150 hours typical (continuous use)
Low Battery: Green LED Off when ≥ 7V
Overload Indication: Red LED indicates input greater than selected range