Emerson CSI 6500 Quick Start Manual page 14

Machinery health monitor a6151, dual channel low frequency shaft vibration monitor
Hide thumbs Also See for CSI 6500:
Table of Contents

Advertisement

Available languages

Available languages

Product Information / Produktinformation A6151
Shaft Vibration Monitor
Signal conditioning
Sensor signal outputs
Channel 1 − SENS 1
Channel 2 − SENS 2
Signal output
Precision
Frequency range
Per. load resistance
Internal resistance
*Depends on the jumper setting J2.
Dynamic outputs
The AC portion of the sensor signal is output as scaled value.
Channel 1 − AC1 / Channel 2 − AC2 z14 / z16* open−circuit and short−circuit proof, non−
Nominal range
Measuring range
Precision
Frequency range
Per. load resistance
Source impedance
Internal resistance
*Depends on the jumper setting J2.
Scaled d.c. Outputs
The DC portion of the sensor signal (proportional to the static distance sensor / measurement
object) is output as standardized DC voltage NGL.
Channel 1 − NGL1 / channel 2 − NGL2 z12 / d12 open circuit and short circuit proof, non
Nominal range
Measuring range
Precision / resolution
Per. load resistance
Internal resistance
Front sockets SMB and/or z14 / z16*, uncoupled,
open circuit and short circuit proof, non reactive.
SMB K1
SMB K2
−1 ... −24 V; signal 1:1 to sensor input signal
±1
of f.s.d.
%
0.2 ... 200 Hz (−3 dB) ±20 %
> 100 kΩ
1 kΩ
reactive
0...20 Vpp
Corresponds to the measuring range configured for
the characteristic value, min. 400 mVpp,
max. 8000 mVpp
±1
of f.s.d.
%
0.2 Hz ... 200 Hz (−3 dB) ±20 %
> 10 kΩ
10 kΩ
Approximately 20 Ω
reactive
0 ... +10 V DC
According to the configured operating range of the
sensor
0 V corresponds to the lower value of the work range
+10 V corresponds to the upper value of the work
range
of f.s.d. / 12 Bit
±1
%
> 10 kΩ
Approximately 50 Ω
Page 14

Advertisement

Table of Contents
loading

Table of Contents