2. ERROR CODE HISTORY DISPLAY
Up to 16 memorized error codes may be displayed for the indoor unit connected to the remote controller.
1. Stop the air conditioner operation.
2. Press the SET TEMPERATURE buttons
or more to start the self-diagnosis.
3. Press the SET TEMPERATURE button to select the error history number.
Lower
0
1
F
E
4. Press the SET TEMPERATURE buttons
or there is no key input for 60 seconds to stop the display.
Raise
2
3
4
5
6
d
c
b
A
9
,
simultaneously for 3 seconds
SU MO TU WE TH FR SA
7
8
,
simultaneously for 3 seconds or more
07-03
Error code
Error history number