ROOM AIR CONDITIONER CEILING type (50Hz) Models Indoor unit Outdoor unit ABY30FBAG AOY30FNBWL ABY30UBAG AOY30UNBWL CONTENTS SPECIFICATIONS ..... . 1 OUTLINE AND DIMENSIONS .
CIRCUIT DIAGRAM Models : ABY30FBAG / AOY30FNBWL INDOOR UNIT DISPLAY BOARD GRAY GRAY CONTROL BOARD WHITE GRAY BLACK BLACK FILTER BLACK BOARD OUTDOOR UNIT FAN MOTOR BLUE BLACK PURPLE INTERNAL WHITE OVERLOAD COMPRESSOR BLACK OUTDOOR PROTECTOR THERMOSTAT TERMINAL FAN MOTOR...
Page 7
Models : ABY30UBAG / AOY30UNBWL INDOOR UNIT DISPLAY BOARD WHITE GRAY CONTROL BOARD WHITE GRAY BLACK BLACK BLACK FILTER BLACK BOARD OUTDOOR UNIT GRAY THERMISTOR TERMINAL BLACK BLUE GRAY PROTECTOR (PIPE TEMP.) INTERNAL COMPRESSOR WHITE OVERLOAD BLACK THERMISTOR BLACK PROTECTOR BLACK (OUTDOOR TEMP.) FAN MOTOR...
ERROR DISPLAY 1. INDOOR UNIT 2. OUTDOOR UNIT ERROR : Heat & Cool model (Reverse cycle) only Operation can be checked by lighting and flashing of the display section OPERATION, TIMER, and VERTICAL SWING When a malfunction occurs in the outdoor unit, the LEDs on the circuit lamps.
PARTS LIST INDOOR UNIT Part No. Part No. Ref. Ord. Ref. Ord. Description Description Q'ty Q'ty ABY30FBAG ABY30UBAG ABY30FBAG ABY30UBAG Air Filter 9359739005 9359739005 338-1 Fixture (Motor) 9359702009 9359702009 Base Assy 9359680000 9359680000 338-2 Fixture (Motor)-B 9359703006 9359703006 Sirocco Fan Assy...
Page 23
OUTDOOR UNIT Part number Part number Ref. Description Ref. Description AOY30FNBWL AOY30UNBWL Top Panel Sub Assy 9374417018 Top Panel Sub Assy 9374417018 Front Panel 9374094066 Front Panel 9374094066 Fan Guard 9374330010 Fan Guard 9374330010 Grip Side 9374173013 Grip Side 9374173013 Service Panel Sub Assy 9374415038 Service Panel Sub Assy...
STANDARD ACCESSORIES The following installation parts are furnished. Use them as required. INDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Name and Shape Q'ty Application Remote Use for air conditioner Coupler heat insulator (large) For indoor side pipe joint control unit operation (Gas pipe) Coupler heat insulator (small)