Installation requirements

Location requirements

Observe all governing ordinances
IMPORTANT:
Specified cabinet-opening dimensions are minimums and must be used.
The cabinet recess must completely enclose all but the face of the oven.
A grounded electrical supply is required. (See Electrical Requirements.)
Put the electrical-supply junction box at most 3" (7.6 cm) below the support platform
within the cabinet. A 1" (2.5 cm) min. diameter hole should be drilled in the right/left
rear corner of the support platform for oven-cable access to the junction box.
NOTE
For under-counter installation, the junction box should be in the adjacent right/left
cabinet. For rear-wall installation, the junction box should be recessed in the upper-
right corner of the cutout.
• The support platform must be solid, level, and flush with bottom of the cabinet cutout.
• Single oven: The floor must support 221 lb (100 Kg).
• Install the oven at least 12" (30 cm) from other appliances.
IMPORTANT: To avoid cabinet damage, check with your builder or cabinet supplier to
ensure the materials used will not discolor, delaminate, or sustain other damage. This
oven complies with the requirements of UL and CSA International, and the maximum
allowable wood-cabinet temperatures of 194 °F (90 °C).